Biological Safety Cabinet - Class II Type B2
- Suraj Kumar
- Jan 18
- 2 min read

Introduction
A Biological Safety Cabinet (BSC) Class II Type B2 is a fully ducted biosafety cabinet designed for laboratories that work with biological agents along with volatile toxic chemicals and radionuclides. Unlike Type A2 cabinets, Type B2 cabinets operate on a 100% exhaust system, ensuring maximum environmental and personnel safety.
What is a Class II Type B2 Biological Safety Cabinet?
The Class II Type B2 BSC provides complete protection by:
Preventing operator exposure through inward airflow
Maintaining product protection with HEPA-filtered vertical laminar downflow
Completely exhausting contaminated air through HEPA filtration
In this system, no air is recirculated inside the cabinet. All air is exhausted outside the laboratory via a hard-ducted exhaust system, making it suitable for chemical-biological combined applications.
Airflow Principle & Working
The cabinet functions on a vertical laminar airflow mechanism:
Room air enters through the front intake grille
Air passes through a supply HEPA filter for product protection
Air moves downward over the work surface
100% of the air is captured, HEPA-filtered, and exhausted outside the building
This airflow design eliminates the risk of chemical vapor buildup inside the work area.
Key Features of Class II Type B2 BSC
100% exhaust, zero air recirculation
Dual HEPA filtration (supply & exhaust)
Hard-ducted exhaust connection
Negative pressure plenums for enhanced safety
Microprocessor-based airflow monitoring system
Audio-visual alarms for airflow imbalance
Stainless steel work surface
Low noise operation despite high exhaust capacity
Compliance with international biosafety standards
Applications
Class II Type B2 Biological Safety Cabinets are recommended for:
Handling toxic, volatile chemicals with biological agents
Work involving radionuclides
Pharmaceutical R&D laboratories
Chemical-biological research facilities
Virology and high-risk microbiology labs
Industrial and government research laboratories
Advantages of Class II Type B2 BSC
Maximum personnel and environmental safety
Eliminates chemical vapor recirculation
Suitable for high-risk applications
Ensures regulatory compliance for mixed-hazard work
Reliable containment under all operating conditions
Maintenance Considerations
Regular HEPA filter integrity testing
Exhaust system inspection and airflow balancing
Continuous monitoring of face velocity
Annual certification by trained professionals
Conclusion
The Biological Safety Cabinet Class II Type B2 is the safest choice for laboratories that require complete exhaust of hazardous biological and chemical contaminants. Its 100% ducted airflow system ensures uncompromised safety, making it essential for advanced research and high-risk laboratory environments.
Specification
MODEL | LMBSF-401 | LMBSF-202 | LMBSF-203 | LMBSF-204 |
TYPE | CLASS II, Type B2 | |||
CHAMBER MATERIAL | COLD-ROLLED STEEL COATED WITH ANTI-BACTERIA POWDER COATING | |||
POWER | 1050 W | 1350 W | 1550 W | 1900 W |
POWER SUPPLY | 350 Kg | 360 Kg | 440 Kg | 470 Kg |
INNER DIMENSION | 940x600x660mm | 1100x600x660mm | 1350x600x620mm | 1600x670x630mm |
OUTER DIMENSION | 1100x750x2250mm | 1300x850x2200mm | 1500x760x2250mm | 1800x840x2275mm |
WEIGHT | 350 Kg | 360 Kg | 440 Kg | 470 Kg |