BIOLOGICAL SAFETY CABINET - CLASS II TYPE A2
- Suraj Kumar
- Jan 17
- 2 min read

Introduction
The LuxMed® Biological Safety Cabinet (BSC) Class II Type A2 – LMBSF-200 Series is engineered to deliver maximum personnel, product, and environmental protection for laboratories handling biological agents. Designed with an inward airflow velocity of 0.55 m/s, HEPA-filtered vertical laminar airflow, and HEPA-filtered exhaust air, this cabinet ensures safe and contamination-free microbiological operations.
It is ideal for laboratories working without volatile or toxic chemicals and radionuclides, as the air is partially recirculated within the work area.
Triple Protection Airflow Design
The LMBSF-200 Series operates on a Class II Type A2 airflow system, providing:
Personnel protection through inward airflow and negative pressure plenums
Product protection via HEPA-filtered vertical laminar downflow
Environmental protection with HEPA-filtered exhaust air
With 70% air recirculation and 30% air exhaust, the cabinet maintains a clean and stable working environment while meeting international biosafety requirements.
Key Features of LuxMed® LMBSF-200 Series
LuxMed BSCs are designed with advanced safety, ergonomics, and intelligence:
Two-layered ≥5 mm marinated toughened glass, motorized front sash
Negative air pressure system for continuous personnel safety
Remote control operation for sash movement and fan speed
Motorized front window with timer function
Digital LCD display for real-time parameter monitoring
UV lamp (253.7 nm) for highly efficient surface decontamination
Foot switch for easy height adjustment of the front window
Two waterproof electrical sockets on the side panel
Adjustable air speed via control panel
4000 ml collecting tank to safely collect working area spatters
Intrinsic sterilization achieved with 30-minute UV timer activation
High-performance blower with double suction capacity (2500–2700 m³/h)
Filter life indicator with pressure value display
SS 304 stainless steel work table
Applications
The LuxMed Biological Safety Cabinet Class II Type A2 is suitable for a wide range of laboratory applications, including:
Microbiological and clinical research
Life science and molecular biology laboratories
Cell culture (plant & animal)
Genetics and biotechnology research
Pharmaceutical and industrial laboratories
Diagnostic and hospital laboratories
Technical Highlights (LMBSF-200 Series)
HEPA Filters: 2 Nos., 99.999% efficiency at 0.3 µm
Inflow Air Velocity: 0.53 ± 0.025 m/s
Downflow Air Velocity: 0.33 ± 0.025 m/s
Noise Level: ≤58 dB(A) – ≤65 dB(A)
Illumination: Up to 1200 Lux
Control System: Microprocessor-based with VFD
Safety Opening Height: ≤200 mm
Power Supply: 230–240 V, 50/60 Hz
Available Models: LMBSF-201 to LMBSF-205 (multiple working widths)
Why Choose LuxMed® BSC Class II Type A2?
International-grade biosafety compliance
Robust construction with antibacterial powder coating
Intelligent safety interlocks and alarms
Ergonomic, user-friendly design
Reliable performance with low operating cost
Conclusion
The LuxMed® Biological Safety Cabinet Class II Type A2 – LMBSF-200 Series is a trusted biosafety solution for laboratories requiring high-level protection, operational efficiency, and regulatory compliance. With advanced airflow engineering, intelligent controls, and premium build quality, it supports safe and precise biological research across diverse applications.
Model | LMBSF-201 | LMBSF-202 | LMBSF-203 | LMBSF-204 | LMBSF-205 |
TYPE | CLASS II,TYPE A2 | ||||
CHAMBER MATERIAL | COLD-ROLLED STEEL COATED WITH ANTI-BACTERIA POWDER COATING | ||||
POWER | 760 w | 800 w | 900 w | 900 w | 1500 w |
POWER SUPPLY | 230V/240V, 50 Hz/60Hz | ||||
INNER DIMENSION | 940x600x660mm | 1150x600x660mm | 1350x600x660mm | 1710x600x660mm | 1800x600x660mm |
OVERALL DIMENSION | 1100x750x2250mm | 1300x850x2250mm | 1500x750x2250mm | 1870x750x2290mm | 1950x800x2305mm |
WEIGHT | 243 kg | 280 kg | 316 kg | 395 kg | 420 kg |